Ínicio Ínicio Downloads

Home > Solutions > Products > CM-VRT

Back to Products and Solutions

CM-VRT

Complete AC/DC Converter System for Electromagnets

The Varixx AC/DC Converter Panel is an advanced and efficient solution for supplying power to electromagnets, designed to ensure precise control and maximum safety. Equipped with two three-phase rectifier bridges, the panel converts alternating current into direct current, essential for the operation of electromagnets.


High durability – over 200 million operations, with no mechanical wear. Low maintenance – does not require periodic servicing, reducing operational costs. Precise demagnetization control – adjustable time from 0.4 to 10 seconds Integrated safety – protections against overload, short-circuit, fuse failure, and emergency stop button. Silent and reliable operation - no vibration, noise or overvoltages. Compact and efficient design – saves panel space and features standardized plug-in modules (50A to 300A).

Designed to facilitate installation and optimize the use of space, this system incorporates the MAG V electromagnet controller.
Complete System Solution

Demagnetization Control

This system stands out for its adjustable control of the demagnetization time, which varies between 0.4 and 10 seconds, adapting to the specific needs of each application. The flexibility in adjusting the time allows for effective customization, optimizing the demagnetization process according to the operational demand of the electromagnets.

Incorporates GE Multilin, Varixx or other

Fully isolated low voltage module

Incorporates starting resistance (shunt) for “Slip Ring” motors

Modbus communication (other optional protocols)

Designed for internal arc resistance in compliance with standards

Dielectric strength 2500V
Built-in protections

Converter overload Protects the converter from damage by interrupting current when excessive load is detected.

Short circuit in the converter Switches the converter off immediately in the event of a short circuit to avoid further damage.

Fuse blown indication It alerts about damaged fuses, facilitating rapid maintenance and replacement.

Emergency button Allows instant interruption of operations in risky situations, guaranteeing safety.
Technical specifications

Demagnetization

0.4 to 10 seconds


Nominal Currents

50 to 300 A CC


Command Voltages

110VAC and 220VAC


Lifetime

Greater than 20 years or 200 million maneuvers.


Output Voltage

35% higher than the input voltage


Fan Voltage

110 or 220 VAC


Maximum Input Voltage

300 VAC



Downloads

Catálogos
Manuais

Talk to our consultants

Discover how Varixx can boost your business

Related Products

CM-VRT Electromagnet Drive Access Evomag Electromagnet Drive Access Indoor luminaires Highbay luminaires Indoor luminaires Highbay luminaires Indoor luminaires Highbay luminaires Indoor luminaires Highbay luminaires Indoor luminaires Highbay luminaires Indoor luminaires Highbay luminaires Indoor luminaires Highbay luminaires Indoor luminaires Highbay luminaires Indoor luminaires Highbay luminaires Indoor luminaires Highbay luminaires Indoor luminaires Highbay luminaires Indoor luminaires Highbay luminaires